Serpentine II, IV Triple Pass Heaters
Specifications:
- Air temperatures controllable to 1500°F (815°C)
- Serpentine II to 3.6kW
- Serpentine VI to 8.0kW
- Triple Pass Heat Exchanger uses incoming air to cool outer shell
- Maximum air pressure 25 PSI (1.7 Bar)
- Replaceable element assemblies
- CE compliant
|
 |
| Installation
|
Products
| Serpentine II Elements used with housing 029763 |
| Part Number |
Max. Watts |
Max. Volts |
Max. Amps |
Length "A" |
O.D. "B" |
| 029765 |
2kW |
240 |
8.3 |
8.20" (208mm) |
0.63" (16mm) |
| 029766 |
2.8kW |
240 |
11.7 |
8.20" (208mm) |
0.63" (16mm) |
| 029767 |
3.6kW |
240 |
15 |
8.20" (208mm) |
0.63" (16mm) |
| 060418 |
3.6kW (Two-stage) |
240 |
15 |
8.63" (219mm) |
0.63" (16mm) | |
| Serpentine VI Elements used with housing 057088 |
| Part Number |
Max. Watts |
Max. Volts |
Max. Amps |
Length "A" |
O.D. "B" |
| 040291 |
5kW |
240 |
20.8 |
10.88" (276mm) |
1.25" (32mm) |
| 040292 |
6kW |
240 |
25 |
10.88" (276mm) |
1.25" (32mm) |
| 061429 |
6kW (Two-stage) |
240 |
25 |
10.88" (276mm) |
1.25" (32mm) |
| 056548 |
8kW |
240 |
33.3 |
10.88" (276mm) |
1.25" (32mm) | |
| Housing Assemblies |
| Part Number |
Serpentine Type |
"A" |
"B" |
"C" |
"D" |
"E" |
| 029763 |
II |
1.6" (40mm) |
9.0" (229mm) |
10.0" (254mm) |
0.7" (18mm) |
3/8" NPT |
| 057088 |
VI |
2.1" (54mm) |
11.9" (302mm) |
12.9" (327mm) |
1.4" (35mm) |
3/4" NPT | |
Accessories
| Part Number |
Description |
| 039739 |
Serp II base adaptor assembly |
| 042339 |
Serp VI base adaptor assembly |
| 029485 |
Serp II TC holder (includes TC) |
| 040299 |
Ser VI TC holder (includes TC) |
| 039272 |
"K" type thermocouple probe, 3/16" (4.8mm) O.D. |
| 066823 |
Closed loop power control, 240V, 30A, 4-20mA |
| 057081 |
Open loop (manual) power control, 240V, 25A |
| 070429 |
Temperature controller - 1/16 DIN, 4-20mA | |
Threaded Inline Heaters
Specifications:
- Air temperatures to 1400°F (760°C)
- For applications requiring high pressure air
- Both ends threaded 3/8", 1/2", 1-1/4", and 2-1/2" NPT
- 304 Stainless Steel housing
- CE compliant
- Style A
- Should be used whenever an absolute leak-proof system (up to 150 PSI) is required
- Two high temperature power feedthroughs
- Maximum inlet temperature 900°F (482°C)
- Style B
- Maximum air pressure 150 PSI, but will have slight air leakage through power wire strands
- 12" (305mm) flexible power wires
- Maximum inlet temperature 200°F (93°C)
|
 |
Installation
 click on image to enlarge |
Products
| Heater Size NPT |
Max. Watts |
Max. Volts |
Max. Amps |
Part No., Style A |
Part No., Style B |
| 3/8" |
1.6kW |
170 |
9.4 |
038821 |
038822 |
| 1/2" |
4.0kW |
220 |
18.2 |
038823 |
038824 |
| 1-1/4" |
6.0kW |
220 |
27.3 |
038825 |
038826 |
| 2-1/4" |
18.0kW |
240 |
75.0(1 )/44.0(3 ) |
N/A |
063007 | |
Accessories
| Part Number |
Description |
| 057081 |
Open loop (manual) power control, 240V, 25A |
| 066823 |
Closed loop power control, 240V, 30A |
| 070429 |
Temperature controller - 1/16 DIN, 4-20mA |
| 039272 |